fix type_error with instantiated EOF -1 byte literal in get_byte/2
According to ISO Prolog, get_byte/2 predicate can receive an instantiated input byte: http://www.gprolog.org/manual/html_node/gprolog037.html#sec156 get_byte(+stream_or_alias, ?in_byte) Since in_byte can be -1 if EOF is reached, instantiating it with -1 should work but does not because the implementation is trying to convert it to a u8 which is unsigned: ?- open("/dev/null", read, S, [type(binary)]), get_byte(S, -1). error(type_error(in_byte,-1),get_byte/2). This commit adds an extra check for -1 before checking for a valid u8 instantiated value if in_byte is an input: ?- open("/dev/null", read, S, [type(binary)]), get_byte(S, -1). S = '$stream'(0x55601e65c998). Closes #1625
This commit is contained in:
@@ -2432,6 +2432,12 @@ impl Machine {
|
|||||||
addr
|
addr
|
||||||
} else {
|
} else {
|
||||||
match Number::try_from(addr) {
|
match Number::try_from(addr) {
|
||||||
|
Ok(Number::Integer(ref n)) if **n == -1_i64 => {
|
||||||
|
fixnum_as_cell!(Fixnum::build_with(-1))
|
||||||
|
}
|
||||||
|
Ok(Number::Fixnum(n)) if n.get_num() == -1_i64 => {
|
||||||
|
fixnum_as_cell!(Fixnum::build_with(-1))
|
||||||
|
}
|
||||||
Ok(Number::Integer(n)) => {
|
Ok(Number::Integer(n)) => {
|
||||||
if let Some(nb) = n.to_u8() {
|
if let Some(nb) = n.to_u8() {
|
||||||
fixnum_as_cell!(Fixnum::build_with(nb as i64))
|
fixnum_as_cell!(Fixnum::build_with(nb as i64))
|
||||||
|
|||||||
Reference in New Issue